Memorias de investigación
Ponencias en congresos:
Reliability and reproductibility of skin temperature of overweight subjects by an infrared thermograpy software designed for human beings
Año:2013

Áreas de investigación
  • Ciencias naturales y ciencias de la salud,
  • Humanidades y ciencias sociales

Datos
Descripción
The technical improvement and new applications of Infrared Thermography (IRT) with healthy subjects should be accompanied by results about the reproducibility of IRT measurements in different popula-tion groups. In addition, there is a remarkable necessity of a larger supply on software to analyze IRT images of human beings. Therefore, the objectives of this study were: firstly, to investigate the reproducibility of skin temperature (Tsk) on overweight and obese subjects using IRT in different Regions of Interest (ROI), moments and side-to-side differences (?T); and secondly, to check the reliability of a new software called Termotracker®, specialized on the analysis of IRT images of human beings. Methods: 22 overweight and obese males (11) and females (11) (age: 41,51±7,76 years; height: 1,65±0,09 m; weight: 82,41±11,81 Kg; BMI: 30,17±2,58 kg/m²) were assessed in two consecutive thermograms (5 seconds in-between) by the same observer, using an infrared camera (FLIR T335, Sweden) to get 4 IRT images from the whole body. 11 ROI were selected using Termotracker® to analyze its reproducibility and reliability through Intra-class Correlation Coefficient (ICC) and Coefficient of Variation (CV) values. Results: The reproducibility of the side-to-side differences (?T) between two consecutive thermograms was very high in all ROIs (Mean ICC = 0,989), and excellent between two computers (Mean ICC = 0,998). The re-liability of the software was very high in all the ROIs (Mean ICC = 0,999). Intraexaminer reliability analysing the same subjects in two consecutive thermograms was also very high (Mean ICC = 0,997). CV values of the different ROIs were around 2%. Conclusions: Skin temperature on overweight subjects had an excellent reproducibility for consecutive ther-mograms. The reproducibility of thermal asymmetries (?T) was also good but it had the influence of several factors that should be further investigated. Termotracker® reached excellent reliability results and it is a relia-ble and objective software to analyse IRT images of humans beings.
Internacional
Si
Nombre congreso
12th Eurpean Congress of Thermology
Tipo de participación
960
Lugar del congreso
Porto, Portugal
Revisores
Si
ISBN o ISSN
1560-604X
DOI
Fecha inicio congreso
05/09/2012
Fecha fin congreso
08/09/2012
Desde la página
130
Hasta la página
137
Título de las actas
Book of Proceedings of the 12th European Congress of Thermology Porto, 2012, 5th ? 8th September

Esta actividad pertenece a memorias de investigación

Participantes

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Deporte Rendimiento
  • Departamento: Deportes