Observatorio de I+D+i UPM

Memorias de investigación
Communications at congresses:
Response Matrix of a BSS / 6LiI(Eu)
Year:2008
Research Areas
  • Naval engineering
Information
Abstract
Using Monte Carlo methods the response matrix of a Bonner sphere spectrometer with a 6LiI scintillator has been calculated. The response was calculated for 0, 5.08, 7.62, 12.7, 20.32, 25.4, and 30.48 cm-diameter polyethylene spheres using twenty three monoenergetic neutron sources whose energy varies from 2.50E(-8) to 100 MeV. The response functions were interpolated to thirty one and fifty one neutron energies and compared with two response functions reported in the literature, a good agreement was found from this comparison.
International
Si
Congress
ICRS-11 - 11th International Conference on Radiation Shielding & RPSD-2008 ¿ 15th Topical Meeting of the Radiation Protection & Shielding Division of ANS
960
Place
Pine Mountain, Georgia (EE.UU.)
Reviewers
Si
ISBN/ISSN
ISSN:0029-5450
Start Date
13/04/2008
End Date
18/04/2008
From page
1
To page
5
Nuclear Technology
Participants
  • Autor: H.R. Vega-Carrillo (Universidad Autónoma de Zacatecas)
  • Autor: Alfredo Lorente Fillol (UPM)
  • Autor: E. Manzanares Acuña (Universidad Autónoma de Zacatecas)
  • Autor: Eduardo Florentino Gallego Diaz (UPM)
Research Group, Departaments and Institutes related
  • Creador: Departamento: Ingeniería Nuclear
S2i 2019 Observatorio de investigación @ UPM con la colaboración del Consejo Social UPM
Cofinanciación del MINECO en el marco del Programa INNCIDE 2011 (OTR-2011-0236)