Automatic Cardiac Motion Estimation from Tagged MRI using Multiple Source Non-Rigid Registration Techniques
Year:2007
Research Areas
  • Electronics engineering
Information
Abstract
This study suggests that fully automatic tagged MR image processing is feasible using multiple source non-rigid registration techniques. Subpixel accuracy is achieved thanks to the Bspline image representation. Furthermore, the analytical representation of the deformation is an optimal framework to obtain spatiotemporal derived parameters (such as strain) analytically from the computed displacement field.
International
Si
Congress
Intl. Soc. Mag. Reson. Med (ISMRM-ESMRMB Joint Annual Meeting)
960
Place
Berlin, Alemania
Reviewers
Si
ISBN/ISSN
1545-1428
Start Date
19/05/2007
End Date
25/05/2007
From page
To page
Participants
  • Participante: E. McVeigh (National Institutes of Health)
  • autor: M. Desco (Hospital G.U. Gregorio Marañon)
  • Autor: Maria Jesus Ledesma Carbayo (UPM)
  • autor: S. Sampath (National Institutes of Health)
  • Autor: Andres de Santos Lleo (UPM)
  • autor: J.A. Derbyshire (National Institutes of Health)