Validation of Jaeger Oxycon Mobile portable metabolic system
Año:2007

Áreas de investigación
  • Fisiología

Datos
Descripción
The use of portable metabolic systems has increased during field tests. Thus, the objective of this study was to carry out a validation of Jaeger Oxycon Mobile (OM) portable metabolic system, taking as gold standar the automated metabolic system Jaeger Oxycon Pro (OP), which validity has been demonstrated previously (1). MATERIAL AND METHODS Six subjects participated voluntary in the study. The experimental protocol consisted of two incremental tests on a treadmill with a stepped protocol (2 min for each step) between 11 and 17 Km/h. One or other system was used in each test, in random order, and tests were carried out with one day rest among them. During each step of speed, data for VO2, VCO2, VE and RER were averaged every 15 seconds for its later analysis. The differences in the measures for VO2, VCO2, VE and RER were evaluated with a tStudent test for related samples. To check the validity for OM, Bland and Altman¿s procedure were followed (2). The significance level was fixed at p<0,05. RESULTS All subjects reached a maximum speed of 17 Km/h in both tests, what confirms its reproductibility. The comparision of means showed significant differences for VO2 between 12 and 17 Km/h when both systems were compared. In the same way, significant differences were observed for RER in all speeds except at 11 Km/h. VCO2 showed a tendency to be overestimated by OM, but significant differences were not observed. Likewise, VE didn¿t show significant differences for any speed. Bias for VO2 and RER were 411,65 ± 267,5 ml/min and -0,12 ± 0,06 respectively when data were treated in all. These differences represented a mean error of 8,9 and 12% respectively. For VCO2 and VE, bias were lower, - 39,43 ± 212,6 ml/min and -1,26 ± 8,46 L/min. DISCUSSION The main result of this study showed a OM systematic error in the measurement of VO2 and RER. Since VE didn¿t show significant differences in any case, we can assume that the Triple V R (i. e. volume measurement) makes correct and reliable measures, so the differences found for VO2 could be related with to the different methods used in both devices (3). Our results are consistent with those presented by Perret and Mueller (3), but our bias are larger. This disagreement can be due to the differences in the ergometer used, treadmill in our case. Thus, we conclude that OM makes systematic errors that could be corrected with regression analisys to obtain comparable measurements until manufacturer improve software and hardware.
Internacional
Si
Nombre congreso
12th Annual Congress of the European Collegue of Sport Science
Tipo de participación
960
Lugar del congreso
Jyväskylä (Finland)
Revisores
Si
ISBN o ISSN
978-951.790-242-7
DOI
Fecha inicio congreso
11/07/2007
Fecha fin congreso
14/07/2007
Desde la página
Hasta la página
Título de las actas

Esta actividad pertenece a memorias de investigación

Participantes

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Grupo de Inv. del Laboratorio de Fisiología del Esfuerzo