Memorias de investigación
Artículos en revistas:
Segmentation of Multiple Heart Cavities in 3-D Transesophageal Ultrasound Images
Año:2015

Áreas de investigación
  • Ingenierías,
  • Tecnología electrónica y de las comunicaciones

Datos
Descripción
Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7?2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations.
Internacional
Si
JCR del ISI
Si
Título de la revista
Ieee Transactions on Ultrasonics, Ferroelectrics, And Frequency Control
ISSN
0885-3010
Factor de impacto JCR
1.512
Información de impacto
Volumen
62
DOI
10.1109/TUFFC.2013.006228
Número de revista
6
Desde la página
1179
Hasta la página
1189
Mes
JUNIO
Ranking
Acoustics: 10/31 (Q2)

Esta actividad pertenece a memorias de investigación

Participantes

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Tecnología de imágenes biomédicas
  • Departamento: Ingeniería Electrónica