Within the complexity of the design and execution of a solar power plant project, one of the main challenges falls on rainwater management, since there is the need to collect, conduct and store it for its use in the water-vapour cycle process. Therefore, the primary piping for rainwater ransportation from the solar power plant is regarded as an essential installation for the operation of the plant. Within this framework, the appearance of pathologies in its conduction just a few months after the plant start-up is considered to be a critical problem, as it can endanger the electrical production of the facility.
Internacional
Si
JCR del ISI
Si
Título de la revista
Engineering Failure Analysis
ISSN
1350-6307
Factor de impacto JCR
1,358
Información de impacto
Volumen
DOI
10.1016/j.engfailanal.2017.04.005
Número de revista
Desde la página
1
Hasta la página
31
Mes
SIN MES
Ranking

Esta actividad pertenece a memorias de investigación

Participantes
  • Autor: Celestino González-Nicieza Universidad de Oviedo
  • Autor: Victor Ordiales Martinez Universidad de Oviedo
  • Autor: Ricardo Lain Huerta UPM
  • Autor: Carlos Lain Huerta UPM
  • Autor: M. Inmaculada Alvarez-Fernandez Universidad de Oviedo

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Ingeniería de Georrecursos y Modelización