Descripción
|
|
---|---|
The velocity measured by ultrasonic anemometer in static tests is calibrated with pitot-tube data, and the interpolation of obtained calibration coefficients is used to correct the ultrasonic velocity measured in dynamic tests. It is observed that the calibrated ultrasonic wind speed measurements in dynamic tests are in a good agreement with the reference velocity. According to the results, the ultrasonic velocity measurements in both static and dynamic tests are affected by the transducers head distortions, and the shifting in acoustic pulse trajectory due to the rotational motion does not affect the anemometer measurements. | |
Internacional
|
Si |
JCR del ISI
|
Si |
Título de la revista
|
Measurement |
ISSN
|
0263-2241 |
Factor de impacto JCR
|
2,359 |
Información de impacto
|
Datos JCR del año 2016 |
Volumen
|
114 |
DOI
|
10.1016/j.measurement.2017.09.050 |
Número de revista
|
|
Desde la página
|
356 |
Hasta la página
|
371 |
Mes
|
ENERO |
Ranking
|