Descripción
|
|
---|---|
Using Monte Carlo methods the response matrix of a Bonner sphere spectrometer with a 6LiI scintillator has been calculated. The response was calculated for 0, 5.08, 7.62, 12.7, 20.32, 25.4, and 30.48 cm-diameter polyethylene spheres using twenty three monoenergetic neutron sources whose energy varies from 2.50E(-8) to 100 MeV. The response functions were interpolated to thirty one and fifty one neutron energies and compared with two response functions reported in the literature, a good agreement was found from this comparison. | |
Internacional
|
Si |
Nombre congreso
|
ICRS-11 - 11th International Conference on Radiation Shielding & RPSD-2008 ¿ 15th Topical Meeting of the Radiation Protection & Shielding Division of ANS |
Tipo de participación
|
960 |
Lugar del congreso
|
Pine Mountain, Georgia (EE.UU.) |
Revisores
|
Si |
ISBN o ISSN
|
ISSN:0029-5450 |
DOI
|
|
Fecha inicio congreso
|
13/04/2008 |
Fecha fin congreso
|
18/04/2008 |
Desde la página
|
1 |
Hasta la página
|
5 |
Título de las actas
|
Nuclear Technology |