Descripción
|
|
|---|---|
| This paper presents a study about the influence of the current consumed by the high-speed trains on this novel ground fault identification method. The operation of the method is correct even with the highspeed train currents in the section with a ground fault. This fact has been validated through numerous computer simulations, obtaining excellent results. | |
|
Internacional
|
Si |
|
Nombre congreso
|
15th International Conference on Railway Engineering Design and Operation, COMPRAIL 2016 |
|
Tipo de participación
|
960 |
|
Lugar del congreso
|
Madrid |
|
Revisores
|
Si |
|
ISBN o ISSN
|
2058-8305 |
|
DOI
|
|
|
Fecha inicio congreso
|
19/07/2016 |
|
Fecha fin congreso
|
21/07/2016 |
|
Desde la página
|
250 |
|
Hasta la página
|
261 |
|
Título de las actas
|
Influence of High-Speed Train Power Consumption on a Novel Ground Fault Identification Method for 2 x 25 kV Railway Power Supply Systems |