Descripción
|
|
|---|---|
| The aim of this paper is to show UPM¿s measurement facilities and some first studies of its capabilities to hold a millimetre wave antenna measurement system. The current laboratory is able to measure up to 40 GHz in different configurations. Its installations consist on three chambers, each one dedicated to a particular measurement scheme. In this communication, we will carry out a brief state of art review. Then, we will focus on studying quiet zone simulations at 100GHz for our compact range set-up. These calculations are early behaviour studies of the UPM serrated main reflector using PO skills and analytic calculus techniques. This work is a part of the Terasense project in the fields of antenna measurement and design. | |
|
Internacional
|
No |
|
Nombre congreso
|
XXIV Simposium Nacional de la Unión Científica Internacional de Radio (URSI) |
|
Tipo de participación
|
960 |
|
Lugar del congreso
|
SANTANDER |
|
Revisores
|
Si |
|
ISBN o ISSN
|
978-84-8102-550-7 |
|
DOI
|
|
|
Fecha inicio congreso
|
16/09/2009 |
|
Fecha fin congreso
|
18/09/2009 |
|
Desde la página
|
1 |
|
Hasta la página
|
4 |
|
Título de las actas
|
Actas del simposio Nacional de la URSI |