Aerodynamic Analysis of Cup Anemometers Performance: The Stationary Harmonic Response
Año:2013
Áreas de investigación
  • Ingeniería mecánica, aeronaútica y naval
Datos
Descripción
The effect of cup anemometer shape parameters, such as the cups? shape, their size, and their center rotation radius, was experimentally analyzed. This analysis was based on both the calibration constants of the transfer function and the most important harmonic term of the rotor?s movement, which due to the cup anemometer design is the third one. This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer?s rotor and the mentioned third harmonic term of its movement.
Internacional
Si
JCR del ISI
Si
Título de la revista
The Scientific World Journal
ISSN
1537-744X
Factor de impacto JCR
1,73
Información de impacto
Volumen
2013
DOI
10.1155/2013/197325
Número de revista
Desde la página
0
Hasta la página
11
Mes
SIN MES
Ranking
0
Esta actividad pertenece a memorias de investigación
Participantes
  • Autor: Santiago Pindado Carrion (UPM)
  • Autor: Javier Cubas Cano (UPM)
  • Autor: Angel Pedro Sanz Andres (UPM)
Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Desarrollo y Ensayos Aeroespaciales
  • Centro o Instituto I+D+i: Instituto Universitario de Microgravedad "Ignacio da Riva"
  • Departamento: Infraestructura, Sistemas Aeroespaciales y Aeropuertos
  • Departamento: Vehículos Aeroespaciales
S2i 2022 Observatorio de investigación @ UPM con la colaboración del Consejo Social UPM
Cofinanciación del MINECO en el marco del Programa INNCIDE 2011 (OTR-2011-0236)
Cofinanciación del MINECO en el marco del Programa INNPACTO (IPT-020000-2010-22)