Memorias de investigación
Ponencias en congresos:
Metal-less V-groove RXI collimator
Año:2011

Áreas de investigación
  • Ingenierías

Datos
Descripción
A metal-less RXI collimator has been designed using the Simultaneous multiple surface method (SMS). The collimator is completely made of plastic (PMMA) and does not include any mirrored surface, unlike to the convectional RXI collimators, whose back surface is metalized to provide a specular reflection. The back surface of the V-groove RXI is designed as a grooved surface providing two TIR reflections for all rays impinging on it. The main advantage of the presented design is lower manufacturing cost since there is no need for the expensive process of metalization. Also, unlike to the conventional RXI collimators this design performs good colour mixing. The experimental measurements of the first prototype are presented.
Internacional
Si
Nombre congreso
Illumination Optics II
Tipo de participación
960
Lugar del congreso
Marsella, Francia
Revisores
Si
ISBN o ISSN
0277-786X
DOI
Fecha inicio congreso
07/09/2011
Fecha fin congreso
08/09/2011
Desde la página
1
Hasta la página
2
Título de las actas
PROCEEDINGS OF SPIE Volume 8170 Proceedings of SPIE, 0277-786X, v. 8170 Illumination Optics II

Esta actividad pertenece a memorias de investigación

Participantes

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Ingeniería Óptica
  • Centro o Instituto I+D+i: Centro de Domótica Integral, CEDINT
  • Departamento: Electrónica Física