Descripción
The aerodynamics of rotatory elements is an extremely interesting topic that has brought attention of many researchers since the early works by Ludwig Prandtl. A clear example of rotational aerodynamics is the classic cup anemometer. In this research, anemometers equipped with opto-electronic output signal generators based on slotted wheels have been tested, their output signals being studied. The analysis of the output signal of the classic cup anemometer has a great relevance in the correct measurement of the wind speed. This correct analysis can help understand non-steady phenomena of the wind such as turbulence, optimize their maintenance, and also improve the study of the appropriate manufacture of the anemometers. Slight deviations on cup anemometer wind speed measurements may lead to non-optimal policies in wind turbine?s control, decreasing the economic revenue of the corresponding wind power plant. These deviations may be caused by two main different problems, among others. On the one hand, the processing method used to extract the rotation/output frequency if the sensor and, on the other hand, turbulence of the flow and measurement errors present in the slotted wheel of the opto-electronic output signal generator of the anemometer. Two different processing methods to extract the aforementioned output frequency have been tested, namely the Fast Fourier Transform (FFT) and the counting pulses method (CP). These methods have been tested for different sampling frequencies and sampling time. The influence of the frequency is significant for both methods, but CP has been observed to have smaller residuals, especially at high sampling frequencies. The residuals have been observed to reach a constant value for both processing methods after a certain in value of the sampling frequency has been researched. Regarding sampling times, both methods decrease the residuals when the sampling time is increased, but the trend is more significant for CP. Turbulence and other errors affect the signature (the train of pulses during one turn). The signature has been studied at very high sampling frequency (125 kHz). The tests have been performed in a wind tunnel under an ISO 17025 standard. Additional tests of the anemometer in still air and without cups have been performed. In those tests, the anemometer has been driven with a DC motor. Both cases have been compared analysing the first twelve Fourier harmonic terms.
Internacional
Si
Nombre congreso
8th European Conference for Aeronautics and Space Sciences
Tipo de participación
960
Lugar del congreso
Madrid
Revisores
Si
ISBN o ISSN
2493-3503
DOI
Fecha inicio congreso
01/07/2019
Fecha fin congreso
04/07/2019
Desde la página
1
Hasta la página
13
Título de las actas
8th European Conference for Aeronautics and Space Sciences

Esta actividad pertenece a memorias de investigación

Participantes

Grupos de investigación, Departamentos, Centros e Institutos de I+D+i relacionados
  • Creador: Grupo de Investigación: Desarrollo y Ensayos Aeroespaciales
  • Departamento: Aeronaves y Vehículos Espaciales
  • Centro o Instituto I+D+i: Instituto Universitario de Microgravedad "Ignacio da Riva"
  • Departamento: Sistemas Aeroespaciales, Transporte Aéreo y Aeropuertos