Memorias de investigación
Communications at congresses:
Performance comparison of biophotonic sensing cells
Year:2009

Research Areas
  • Magnetic materials

Information
Abstract
The process of detecting specified pathogens or proteins is done by immobilizing the proper bio-receptors on specific sensing areas. Then the analytes will be introduced in those specific areas and react by a process in which only the target biomolecules will be bound with its corresponding biomolecular receptor. In label-free biosensing this binding process is monitored most of the times by photonic sensing structures which are highly sensitive to small refractive index variations provoked for this binding interaction. One of the bio-photonic sensing schemes recently proposed have been based on the holistic approach that combines bio-photonic sensing cells and advanced sub-micron spot size optical interrogation technologies, in which the bio-optical detection system use a tightly focused beam which allows measuring in situ micron/sub-micron size domains, making the routine screening more cost-effective and suitable to perform hundreds of measurements on a single or several samples for multi-single or multiparameter measurements. This proposed bio-optical detection concept will be tremendously sensitive to refractive index variations by means of the observation of the reflectivity profile of three complementary enhanced submicron spot size optical technologies simultaneously (Reflectometry, Spectrometry and Ellipsometry based techniques), and the optical enhancement due to the bio-photonics interferometric or resonant sensing cells, making possible to determine with more re. (POSTER)
International
Si
Congress
E-MRS 2009 Spring Meeting
960
Place
Estrasburgo, Francia
Reviewers
Si
ISBN/ISSN
1546-198X
Start Date
08/06/2009
End Date
12/06/2009
From page
1
To page
1
The proceedings will be published as Sensor Letters Special Issue. (American Scientific Publisher).
Participants
  • Participante: A. Maquiera Departamento de Química. Universidad Politécnica de Valencia.
  • Participante: M.J. Bañuls Departamento de Química. Universidad Politécnica de Valencia.
  • Autor: Miguel Holgado Bolaños UPM
  • Participante: R. Puchades Departamento de Química. Universidad Politécnica de Valencia.
  • Autor: Rafael Casquel Del Campo UPM
  • Autor: Maria Fe Laguna Heras UPM
  • Autor: Carlos Angulo Barrios UPM
  • Autor: Francisco Javier Sanza Gutierrez UPM
  • Autor: David Lopez-Romero Moraleda UPM

Research Group, Departaments and Institutes related
  • Creador: Grupo de Investigación: Ingeniería y Aplicaciones del Láser
  • Centro o Instituto I+D+i: Centro Laser
  • Grupo de Investigación: Grupo de Dispositivos Semiconductores del ISOM
  • Centro o Instituto I+D+i: Instituto Universitario de Sistemas Optoelectrónicos y Microtecnología
  • Departamento: Física Aplicada a la Ingeniería Industrial